Processing Parameters (appliable to MiniSTAR®, MiniSTAR®S, and Biostar®)
Thickness(mm) |
Temperature(℃) |
Heating time(s) |
Pressure(bar) |
0.40 |
220 |
15-20 |
3.2-3.5 |
0.63 |
220 |
25-30 |
3.5-4.0 |
0.76 |
220 |
30-35 |
3.5-4.2 |
1.00 |
220 |
30-40 |
3.8-4.5 |
Processing Parameters (appliable to Druformat Scan &Erkodent®Units)
Thickness(mm) |
Temperature(℃) |
Pressure time(s) |
0.76 |
170-180 |
30-40 |
Note: Heating times vary between different machines.
Ø If the plastic sheet doesn’t form well to the model, add 3-5 seconds on heating time until confirmation is acceptable.
Ø Please be aware that higher pressure and/or longer heating time may cause the risk of a thinner aligner.
Ø If the plastic forms folds or abnormal deformation, reduce the heating time until folds do not occur.
Ø Should you have any further questions about handling our material, please contact [email protected]